Vacuum Stability Testing
Vacuum Stability Testing (VST, VTS) is widely used for reliable risk and safety management of single or double based gun powders, rocket fuels and other propellants, pyrotechnic mixtures, high explosives, hazardous chemicals, energetic polymers, binders and others. An integral part of this monitoring is also a testing of mixtures compatibility. Vacuum conditions provide the highest sensitivity for evolved gas quantification but testing conditions can be widely extended. Stability and compatibility consideration is deeply incorporated in the quality and safety management of production, storage and warehousing. All explosives containing products require certain inspections during their lifecycle. Some of them are inspected only during production but most of them are monitored periodically and their shelflife is strictly controlled.
A series of accidents of automotive parts with propellants and pyrotechnics proved the necessity of VST implementation into R&D and QC of civilian production. These new applications come with demanding requirements and sets the new technological level of VST performance.
GENERAL SPECIFICATIONS
DELTI-Vac is designed as a modular system that follows the maximal easiness and complexity of the application. Each component can be selected from a range of equipment to reach required testing conditions in a regime of vacuum, inert gas, air or oxygen.
Typical sample weight | 5 grams |
Typical testing temperature | 90 - 120 °C |
Typical testing time | 40 - 48 hours |
Typical vacuum range | 0 - 100 kPa abs. |
Maximum pressure range | 0 - 100 bar abs. |
Typical tube volume | 25 ml |
Maximum testing temperature | + 250 °C |
No. of samples | 12 per block |
Simultaneously operated units | Unlimited clustering |
Download detailed technical specifications of DELTI-Vac MIL here.
Download detailed technical specifications of DELTI-Vac Revolution here.
COMPLIANCE
Explosives testing standards: STANAG 4556, 4147, 4022/4, 4023, 4230, 4284, 4566, MIL-STD-650, STANAG 4178 and AOP-48
Electrical safety: CE, CSA
MULTIFUNCTIONALITY
All-in-One unit DELTI-Vac Revolution is designed to provide unexceptional variability and allows testing according to all major stability standards. Typically followed standards are listed in the table below.
Standard Methods | Alternative Methods |
Abel Heat Test | Vacuum drying chamber |
Methyl Violet Test | Humidity and VOC content |
100° Test | Volume of combustion gases |
Weight Loss Test | Water content in combustion gases |
Bergmann-Junk Test 5A/B/C | Safe and precise distillation |
Artificial Ageing Treatment | Alternative ageing procedures |
Vacuum drying | Detection of runaway tendencies |
Vacuum furnace | Polymer oxygen resistance |
User-Defined Program | Induction period / Explosion Temperature Slow & Large scale DTA |
VST ACCESORRIES
-
No subcategories
VST DELTI-Vac REV(+)
-
No subcategories
VST DELTI-Vac MIL(+)
-
No subcategories